Plans and specifications to review
- Foundation plan, wall sections and below-grade elevations
- Membrane system specification, drainage details and footing or sump plans
Measurement and estimating workflow
- Measure below-grade wall area using verified length and protected height.
- Take off membrane, overlaps, terminations, drainage board and perimeter drains separately.
Worked quantity example
A foundation perimeter of 160 feet at eight feet of protected wall height equals 1,280 square feet of gross membrane coverage before laps and details.
Limits and exclusions
Dampproofing and waterproofing are distinct systems. Confirm groundwater conditions, drainage scope and excavation trade boundaries.