Fireproofing Estimating Software – SFRM & Intumescent | Vega
Estimate SFRM and intumescent fireproofing using protected steel surface, deck coverage, fire ratings, thickness and labor scope.
Plans and specifications to review
- Structural framing plans, member sizes and steel schedules
- Fireproofing specification, rated assembly details and deck protection notes
Measurement and estimating workflow
- Estimate actual exposed steel member and deck protection area.
- Separate SFRM and intumescent materials, thickness, prep, masking and inspection.
Worked quantity example
A ten-foot member with a 2.5-foot coated perimeter has about 25 square feet of coated surface before fittings, repairs and waste.
Limits and exclusions
Floor area is not equivalent to steel coating area. Never guess a tested fire rating or required application thickness.